3. WW series for industrial waste water
WW series membrane modules are mainly
for the treatment of wastewater and
tertiary water treatment. The
wastewater has a complex pollutants
with high concentration, hence the
membrane is always fouled. In order to
maintain a stable operation, a
frequent backwash is obliged. Hence
the anti-fouling ability of the
membrane and its strength are the two
key factors for the membrane
application in waste water. Tri-High's
WW series modules are mainly big size
module which saves the space, it has
unique design on flow channel which
can eliminate the fouling. The fibers
are enforced for resistance to high
pressure flow. The membrane life is
longer.
| Model |
WW8000K
(inout) |
WW8060K
(inout) |
| Design flux(L/h) |
1200-2500 |
1800-3750 |
| Area(m2) |
30 |
43 |
| Recommended P |
0.10~0.12Mpa |
| Back washing P |
5~10% lower than operating pressure |
| Back wash frequency |
30sec/0.5~1 hour |
Applications: industrial waste water,tertiary water,residential waste water,municipal waste water
Advantages: strong,better antifouling,more stable,long life